HCC01-TH-0300/0400/0500H-EP Three Phase Hybrid Inverter

  • Multiple Protection Functions.
  • Built-in overvoltage, undervoltage, overload, short circuit, and overtemperature protection to ensure the safety of the inverter and grid equipment.
  • Provides reliable protection for industrial and residential loads, reducing safety risks.
  • 1. 100% unbalanced output, max. output up to 50% rated power for each phase, Max. charging/discharging current of 50A.
  • 2. Support storing energy from diesel generator, High voltage battery higher efficiency.
  • 3. Max. 10 pcs parallel for on-grid and off-grid operation; Support multiple batteries parallel.
  • 4. AC coupling to retrofit existing solar system, 6 time periods for battery charging/discharging.
Product Parameters
100% three-phase unbalanced output, with each phase capable of delivering up to 50% of the rated power Ac coupling to retrofit existing solar system Max. 16 pcs parallel for on-grid and off-grid operation; Support multiple batteries parallel
Max. charging/discharging current of 135A 48V low-voltage battery. transformer isolation design 6 time periods for battery charging/discharging
Support storing energy from diesel generator

 

Certifications

Product Characteristics

Lcd Display Icons


Basic System Architecture

Data Sheet

Model HCC01-TH-0300H-EP HCC01-TH-0400H-EP HCC01-TH-0500H-EP
PV String Input
Max.DCInput Power(W) 39000 52000 65000
Max.DC Input Voltage(V) 1000
Start-up Voltage (V) 180
MPPT Range (V) 150-850
Full Load MPPT Voltage Range(V) 360-850 360-850 450-850
Rated DC Input Voltage(V) 600
PVInput Current(A) 36+36+36 36+36+36+36
Max.PV Isc(A) 55+55+55 55+55+55+55
No.of MPPT Trackers 3 4
No.of Strings per MPPT Tracker 2+2+2 2+2+2+2
ACInput/Output Data
Rated AC Output Power(W) 30000 40000 50000
Max.AC Output Power(W) 33000 44000 55000
AC Input/Output Rated Current(A) 45.5/43.5 60.7/58.0 75.8/72.5
Max.AC Input/Output Current(A) 50/47.9 66.7/63.8 83.4/79.8
Max.Three-phase Unbalanced Output Current (A) 60 70 83.4
Max.Continuous AC Passthrough(A) 200 200 200
Peak Power (Off Grid) 1.5 times of rated power,10 S
Power Factor 0.8 leading-0.8 lagging
Output Frequency and Voltage 50/60Hz;3L/N/PE 220/380Vac 230/400Vac
Grid Type Three Phase
Total Harmonics Distortion(THDi) <3%(of nominal power)
DC Current Injection <0.5%In
Battery
Battery Type Lithium-ion
Battery Voltage Range(V) 160-800
Max.Charging Current(A) 50+50
Max.Discharging Current (A) 50+50
Number of Battery Input 2
Charging Strategy for Li-lon Battery Self-adaption to BMS
Efficiency
Max. efficiency 97.6%
Euro efficiency 97.0%
MPPTefficiency >99%
Protection
Anti-islanding Protection Yes
PV String Input Reverse Polarity Protection Yes
Insulation Resistor Detection Yes
Residual Current Monitoring Unit Yes
Output Over Current Protection Yes
Output Shorted Protection Yes
Surge Protection Yes
Arc Fault Circuit Interruption(AFCI optional) Yes
Over Voltage Category DC Type I/AC Type ll
Certifications and Standards
Grid Regulation IEC61727/62116,EN50549-1
Safety EMC/Standard IEC/EN 61000-6-1/2/3/4,IEC/EN 62109-1,IEC/EN 62109-2
General Data
Operating Temperature Range(℃) -40-60℃,>45°℃ Derating
Cooling Smart Cooling
Noise(dB) ≤70 dB
Communication with BMS CAN
Monitoring mode WIFI, APP
Weight(kg) 82.5
Size(WxHxD mm) 537W×888H×320.5D(Excluding Connectors and Brackets)
Ingress Protection IP66
Installation Style Wall-mounted
Warranty 5Years(10 Years Optional)