HCC04-SM-0100H-YP Single Phase Hybrid Inverter On-Grid And Off-Grid Operation

  • 1. Colorful touch LCD, lP66 protection degree, Max. 16 pcs parallel for on-grid and off-grid operation.
  • 2. Ac coupling to retrofit existing solar system, support multiple batteries parallel.
  • 3. Max.charging/discharging current of 250A, 6 time periods for battery charging/discharging.
  • 4. Support storing energy from diesel generator.
Product Parameters
Colorful touch LCD, Ip66 protection degree Ac coupling to retrofit existing solar system Max. 16 pcs parallel for on-grid and off-grid operation; Support multiple batteries parallel
Max. charging/discharging current of 135A 6 time periods for battery charging/discharging Support storing energy from diesel generator

 

Certifications

Product Characteristics

Lcd Display Icons


Basic System Architecture

Data Sheet

Model HCCO4-SM-0100H-YP
Battery lnput Data
Battery Type Lead-acid or Lithium-ion
Battery Voltage Range(V) 40-60
Max.Charging Current(A) 210
Max.Discharging Current(A) 210
Charging Strategy for Li-lon Battery Self-adaption to BMS
Number of Battery Input 1
PV String Input Data
Max.PV access Power(W) 20000
Max.PVInput Power(W) 16000
Max.PVInput Voltage(V) 500
Start-up Voltage(V) 125
PVInputVoltage Range(V) 125-500
MPPT Voltage Range(V) 150~425
Full Load MPPT Voltage Range(V) 200~425
Rated PVInput Voltage(V) 370
Max.Operating PV Input Current(A) 32+32
Max.Input Short-Circuit Current(A) 48+48
No.of MPP Trackers/No.of Strings MPPTracker 2/2+2
Max.Inverter Backfeed Current to The Array 0
AC Input Data
Rated AC Input Active Power(W) 10000
Max.ACInput Active Power(W) 11000
Peak Power(off grid)(W) 2times of rated power,10s
Rated AC Input/Output Current(A) 45.5/43.5
Max.Rated AC Input/Output Current(A) 50/47.9
Max.Continuous AC Passthrough(grid to load)(A) 50
Max.Output Fault Current(A) 100
Max.Output Overcurrent Protection(A) 140
RatedInput Voltage/Range(V) 220V/230V 0.85Un-1.1Un
Grid Connection Form L+N+PE
Rated Input Grid Frequency/Range 50Hz/45Hz-55Hz 60Hz/55Hz-65Hz
Power Factor Adjustment Range 0.8 leading-0.8 lagging
Total Hamonic Distortion(THDi) <3%(of nominal power)
DC Injection Current <0.5%In
Efficiency
Max.Efficiency 97.60%
Euro Efficiency 96.50%
MPPT Efficiency >99%
Equipment Protection
DC Polarity Reverse Connection Protection Yes
AC Output Overcurrent Protection Yes
AC Output Overvoltage Protection Yes
AC Output Short Circuit Protection Yes
Thermal Protection Yes
DC Terminal Insulation Impedance Monitoring Yes
DC Component Monitoring Yes
Ground Fault Current Monitoring Yes
Arc fault circuit interrupter(AFCI) Optional
Power Network Monitoring Yes
Island Protection Monitoring Yes
Earth Fault Detection Yes
DC Input Switch Yes
Overvoltage Load Drop Protection Yes
Residual Current(RCD)Detection Yes
Surge Protection Level Type II(DC)/Type I(AC)
Interface
Display LCD+LED
Communication Interface RS232,RS485,CAN
Monitor Mode GPRS/WIFI/Bluetooth/4G/LAN(optional)
General Data
Operating Temperature Range -40 to+60℃,>45℃ Derating
Permissible Ambient Humidity 0-100%
Permissible Altitude 2000m
Noise(dB) <30 dB
Ingress Protection(IP)Rating IP66
Inverter Topology Non-lsolated
Over Voltage Category OVCI(DC),OVCⅢ(AC)
Weight(kg) 25
Cabinet size(mm)(W×H×D)
(Excluding connectors and brackets)
316×438×168.5
Warranty Standard 5 years, extended warranty
Grid Regulation Intelligent Air Cooling
Type of Cooling IEC61727,IEC 62116,EN 50549
Safety EMC/Standard IEC/EN 61000-6-1/2/3/4,IEC/EN 62109-1,IEC/EN62109-2